Abstract
The use of annular one-dimensional (1D) photonic crystals (PCs) for salinity sensing is studied in this research. Annular 1D-PCs provide small and integrated structures that facilitate the creation of portable and miniaturized sensor equipment appropriate for field use. In order to generate annular 1D-PCs, the research explores the finite element method (FEM) simulation technique utilizing the COMSOL Multiphysics approach, highlighting the significance of exact control over layer thickness and uniformity. Furthermore, we construct a 1D annular PCs structure in the form ({(AB)}^{N}), where A is silicon ((Si)) and B is silicon dioxide (({SiO}_{2})) of 40 nm and 70 nm, respectively, with a number of periods equal to 9. By incorporating a central defect layer of saline water (220 nm thickness), the sensor achieves optimum performance at normal incidence with a sensitivity (S) of (782 (nm/RIU)), a quality factor (Q) of 10.22, and a figure of merit (FOM) of (12.6 {RIU}^{-1}). The design that is suggested has several advantages over past work on planners and annular 1D-PCs, including ease of implementation, performance at normal incidence, and high sensitivity.
Introduction
In many areas, such as environmental monitoring, agriculture, and desalination processes, salinity is an important characteristic1,2. Thus, the creation of effective and trustworthy salinity sensors is crucial3. One-dimensional photonic crystals (1D PCs) have attracted a lot of attention recently as potential platforms for optical sensing applications4,5,6. Additionally, two-dimensional photonic crystals (2D PCs) have a broadband for salinity detection7,8, however, researchers and scientists prefer to employ one-dimensional photonic crystals (1D PCs) due to their benefits of being simple to make and having a number of uses. Hence, these structures from 1D PCs, comprising alternating layers of materials with high and low refractive indices, exhibit unique optical properties such as photonic bandgaps (PBG) that can be tailored to specific wavelengths of interest. One configuration of 1D PCs that has shown promise for salinity sensing is the annular geometry, where the layers are arranged in concentric rings. Numerous benefits of the circular design include improved sensitivity, compactness, and ease of production9. It is possible to optically detect changes in the local refractive index brought on by salinity variations by inserting ion-selective membranes or hydrogels into the annular 1D PC structure10. This offers a non-intrusive and label-free method for salinity sensing.
Annular 1D PCs offer unique advantages for salinity sensing applications11,12,13. The annular design, consisting of concentric rings of materials with a high and low refractive index, enables improved sensitivity and compactness compared to traditional planar configurations14. Due to the improved interaction between the sensing components and the incident light made possible by this design, the local refractive index changes brought on by salinity variations are more detectable15. An adaptable and scalable manufacturing process can be used to fabricate annular 1D PCs using methods including thin-film deposition, lithography, and etching16. Numerous elements can affect the performance of annular 1D PC salinity sensors, including the choice of material17, layer thicknesses, and the presence of ion-selective membranes or hydrogels. These factors can be optimized to achieve high sensitivity, selectivity, and stability18,19. Additionally, the compact and integrated nature of annular 1D PCs allows for the development of miniaturized and portable sensing devices20,21, suitable for field applications and real-time monitoring.
In annular 1D PC salinity sensors, the shift in the photonic bandgap is typically measured through optical characterization techniques22,23,24. These techniques rely on monitoring changes in the transmission or reflection spectra of the annular 1D PC structure. The reflected or transmitted light is then collected and analyzed using a spectrometer or a tunable filter25. The generated spectrum gives details about the sensor’s photonic band gap. The local refractive index of the surrounding medium alters as the saline concentration does26, which results in a shift in the position or size of the photonic band gap. The reflected or transmitted light spectrum varies in accordance with this shift. The shift in the photonic band gap can be identified by contrasting the resulting spectrum with a reference spectrum captured at a known salinity condition. Overall, the shift in the photonic band gap of annular 1D PC salinity sensors may be precisely quantified by observing the variations in the reflected or transmitted light spectrum, offering a dependable and non-invasive way for salinity detection27. The potential applications of annular 1D PC salinity sensors are broad. They can be utilized in environmental monitoring to assess water quality in rivers, lakes, and coastal areas28,29,30. In agriculture, these sensors can aid irrigation management by monitoring soil salinity levels31, ensuring optimal crop growth and water usage. Furthermore, in desalination processes, annular 1D PC sensors can assist in monitoring the efficiency and effectiveness of desalination techniques, contributing to the development of sustainable water treatment solutions32,33.
The design and optimization of 1D-annular PCs as salinity sensors based on the location of the generated photonic band gap is the reason for this paper’s originality. Here, we couple the location of the photonic band gap with the optical characteristics of the saline solution, as well as the thickness and location of the defect layer from the saline solution or other fluids, as it might be utilized as a biosensor. The numerous 1D annular PC structures may thus pinpoint and distinguish the various defect modes in the PBG regions with great accuracy. We will then evaluate the sensor performance by computing a number of parameters, such as the sensitivity (S), the figure of merits (FOM), and the quality factor (Q). In the manuscript’s second section, we then demonstrate our design modeling. Finally, we present the findings and go over our salinity sensor.
Theoretical analysis and modeling
This section examines the theoretical modeling of our structure. As previously stated, our structure is simulated by COMSOL Multiphysics, which depends on the finite element method [FEM]34. As shown in Fig. 1, our design is an annular photonic crystal structure, which is considered a central cylinder coated with a periodic structure from two different materials; therefore, this structure is considered a one-dimensional photonic crystal as the periodic modulation is in one dimension, as shown.
Introducing the light source and detecting the spectrum in practice for a 1D annular PC structure, as shown in Fig. 1, which refers to the direction of the light propagation, could be achieved through several steps. Firstly, we select a suitable light source to illuminate the 1D annular PC structure. The choice of light source depends on the specific wavelength range of interest and the optical properties of the PC structure. Common light sources include lasers, light-emitting diodes (LEDs), or broadband sources such as white light sources or supercontinuum sources. In the second step, the light from the source needs to be coupled into the 1D annular PC structure. This can be achieved using optical fibers, lenses, or other coupling techniques. The specific coupling method may vary depending on the experimental setup and the type of light source used. Thirdly, this step involves measuring the intensity of the transmitted light as a function of wavelength. The transmission can be measured directly by placing a detector on the output side of the PC structure. Alternatively, you can collect the transmitted light and direct it to a spectrometer or an optical spectrum analyzer to obtain a detailed spectral profile. Finally, we analyze the obtained transmitted spectrum. This may involve identifying the resonant modes or features associated with the annular PC structure. By analyzing the spectral response, we can determine the wavelength shifts or changes induced by different factors, such as the analyte or variations in the environmental conditions.
Here, the radius of the annular photonic crystal structure as shown in Fig. 1 can affect the performance of a salinity sensor based on this design. The radius determines the dimensions and periodicity of the photonic crystal, which in turn influences the propagation of light and the sensitivity of the sensor to changes in salinity. The radius of the annular photonic crystal affects the bandgap properties of the structure. The size of the bandgap is determined by the periodicity of the crystal lattice, which is influenced by the radius. A larger radius typically leads to a wider bandgap, while a smaller radius results in a narrower bandgap. The bandgap properties play a crucial role in the sensor’s performance as a salinity sensor. Changes in the refractive index of the surrounding medium (in this case, seawater with varying salinity) can cause shifts in the bandgap wavelength35,36. By monitoring the shift in the bandgap wavelength, the sensor can infer changes in the salinity of the surrounding environment. The sensitivity of the sensor to changes in salinity can be influenced by the radius of the annular photonic crystal. A smaller radius, leading to a narrower bandgap, may result in higher sensitivity due to a larger shift in the bandgap wavelength for a given change in salinity. Conversely, a larger radius with a wider bandgap may result in lower sensitivity. Thus, the choice of radius in the design of the annular photonic crystal structure for a salinity sensor should be carefully considered to optimize the sensor’s performance and sensitivity to changes in salinity37,38.
Hence, we divided the last structure into four quartiles, as shown in Fig. 2, to save time during simulation. Also, for more precise results, the mesh size should be 10 times smaller than the smallest incidence wavelength. Therefore, we adjust the boundary condition for the structure as shown in Fig. 2. Wherein Fig. 2A represents the incident electromagnetic waves, Fig. 2B represents the transmitted electromagnetic waves, and Fig. 2C represents the scattering boundary conditions. Also, Fig. 3A refers to the perfect matching layers from air for the incident and transmitted waves, and Fig. 3B represents the defect layer from saline water.
Hence, we examine the optical characteristics of water in this part. It is well known that water’s refractive index varies between 1.15 and 1.5 RIU and depends on the incident wavelength. As a result, fresh water has a refractive index of around 1.33 RIU at visible light39. Moreover, water’s extension coefficient varies according to wavelength. Also, the water’s absorption spectrum, given in Fig. 4, supports the idea that water is transparent to the ultraviolet and visible light spectrums due to its low absorption at these wavelengths. However, in the mid- and far-IR spectrums, the water is also substantially absorbed. Salinity (S), which is defined as the quantity of salt in grams dissolved in one kilogram of saltwater and represented in parts per thousand (PPT)40, indicates the amount of salt in seawater. The open ocean’s salinities have been observed to be between 34 and 37 PPT, which may also be expressed as 34 to 37 practical salinity units (PSU). Wherein, seawater with S equal to 35 contains approximately 35 g of salt and 965 g of water, or 35 ppt (35 PSU). Hence, the water could be used for irrigation and human consumption at S ≤ 0.5 (PPT)41,42. As a result, the amount of dissolved salt in water causes a variation in the refractive index from 1.3326 to 1.3505 RIU. Hence, we evaluate the capability of our structure to describe the different refractive indices of saline water as an estimate of the salinity level.
It is important to note that the relationship between salinity and refractive index can be influenced by other factors such as temperature, pressure, and dissolved substances. Thus, as shown in Eq. (1), the refractive index of water is dependent on the following parameters: salinity S (%), seawater temperature (T), and probing wavelength ((lambda )) in nm44,45.
where, S, T, (lambda ) and n denote the salinity (%), temperature (°C), probing wavelength in nm, and refractive index of the saltwater expressed in refractive index units (RIU), respectively.
According to the device structure for a 1D-anuular PC structure shown in Fig. 1, we have many parameters that have an impact on the performance of the device, such as the types of materials used (({n}_{1}, { n}_{2})), the design dimensions (e.g., the cylindrical radius of the center of the device (r), the thickness of each layer (({d}_{1}, { d}_{2})), the number of periods (N)), and the thickness of the defect layer (({d}_{w})). Therefore, in the following part of results and discussions, we study the effect of these last parameters on the sensor performance.
Results and discussions
In this part, we show the results of our design for a 1D-anuular PCs structure. First, we optimize the structure to yield a PBG, as shown in Fig. 5. In Fig. 5, we construct a one-dimensional annular PCs structure in the form ({(AB)}^{N}), where A is silicon ((Si)) with a refractive index (left({n}_{1}right)=3.3)46, and B is silicon dioxide ((Si{o}_{2})) with a refractive index (left({n}_{2}right)=1.46)47. The thicknesses are donated by ({d}_{1}=25 nm), and ({d}_{2}=50 nm) respectively. Thus, we discovered that PBG appears at a number of periods equal to three; thus, increasing the number of periods increases the sharpness of the PBG edges, as shown, as does increasing the number of resonance peaks. Moreover, we illustrate in Fig. 6 the electric field distribution through the considered structure at different numbers of periods. In Fig. 6, we found that the electric field is localized to the silicon dioxide layer as it is the low refractive index layer; therefore, by replacing any layer with saline water, the electric field is localized to it as the refractive index of water is smaller than the refractive index of silicon dioxide.
In Fig. 7, we investigate the effect of silicon dioxide thickness on the position and width of the PBG. Hence, by increasing the thickness of (Si{o}_{2}), the position of the PBG is shifted towards the longer wavelengths, as shown, and the width also increases by increasing the thickness of (Si{o}_{2}), as shown in Table 1. Therefore, we chose to use the larger thickness to get a wider PBG.
Then, we study the effect of the thickness of the silicon layer on the position and width of the PBG. Here, by increasing the thickness of (Si), the position of the PBG is shifted towards the longer wavelengths, as shown in Fig. 8, and the width also increases by increasing the thickness of the (Si) layer, as shown in Table 2. Thus, we chose to use the larger thickness to get a wider PBG. Therefore, we used the consistent materials of 1D annular PCs that consist of (Si) and (Si{o}_{2}), with the thicknesses denoted by 40 nm and 70 nm, respectively.
In general, increasing the thickness of the (Si) layer in a 1D PC structure can result in larger wavelength shifts for a given change in the surrounding medium’s refractive index. Similarly, increasing the (Si{O}_{2}) layer thickness can also lead to larger wavelength shifts. However, it’s important to note that the relationship between the thicknesses and the wavelength shift is not linear and can be influenced by other factors such as the number of periods, the design of the defect layer, and the specific operating conditions. Hence, by varying the thickness of (Si{O}_{2}) at ({d}_{Si}=25 nm), as in Fig. 7, We have the maximum and minimum wavelength shifts for the lift PBG edge at 23 nm and 54 nm, respectively. Also, by varying the thickness of (Si) at ({d}_{Si{O}_{2}}=70 nm), as in Fig. 8, we have the maximum and minimum wavelength shifts of (10 nm) and (78 nm), respectively.
Here, we used the optimum structure from 1D annular PCs that consists of (Si) and (Si{o}_{2}) with the thicknesses of the materials denoted by 40 nm and 70 nm, respectively, with the number of periods equaling 9, and we inserted a central defect layer from saline water with different thicknesses as shown in Fig. 9. In Fig. 9, the PBG for the structure without any defects is extended from 370 to 615 nm, with a width of 245 nm. By inserting a defect layer from saline water with a refractive index equal to 1.3326 and a thickness equal to the lattice parameter of the structure (110 nm), the PBG is extended from 362 to 674 nm with a width equal to 312 nm, and by increasing the thickness of the defect layer to 220 nm, the PBG is extended from 350 to 665 nm, with a defect peak at 623 nm.
Hence, the only case for the structure that yields a defect peak inside the photonic band gap region is that the defect layer thickness is equal to 220 nm, as shown in Fig. 9. Therefore, we choose the last structure with a defect layer equal to 220 nm, and we change the refractive index for the saline water from 1.3326 to 1.3505 to examine the performance of the sensor for changing the refractive index, as shown in Fig. 10. Figure 10A represents the transmission spectrum of the considered structure with a defect layer equal to 220 nm, wherein we have the only difference owing to the change in refractive index at the defect peak as shown. Therefore, we zoom in on this range of the defect peak, as shown in Fig. 10B, to differentiate between the two refractive indices and to calculate and determine the performance of the sensor.
The values of several factors, such as the sensitivity (S), the figure of merits (FOM), and the quality factor (Q), impact the effectiveness and performance of any sensor type. The following formulas are frequently used to determine these parameters48,49.
where, (Delta n,) (Delta lambda ), and ({lambda }_{r}) are the change in refractive index, the differences in wavelengths, and the central wavelength, respectively. The full wave at half maximum is known as FWHM.
Figure 11A represents the sensor for the defect layer thickness, which equals three folds from the lattice parameters (330 nm), and the only difference between the two different refractive indices is the small defect peaks that appear in the PBG region (the green circle). Therefore, we zoom in on these peaks, as shown in Fig. 11B, to examine the performance of the sensor. Wherein the sensitivity equals (139.6 (nm/RIU)), the quality factor equals 170, and the figure of merit equals (60.7 {RIU}^{-1}). As the following calculations show.
Finally, we investigate the impact of incident angle on the sensor performance with the thickness of the defect layer equal to 220 nm to differentiate between the different refractive indices, as shown in Fig. 12. In Fig. 12, we found that by increasing the incident angle, the sensor’s performance decreased. Therefore, the best performance is achieved at normal incidence for a saline water layer thickness of 220 nm. Thereby, we summarize the previous results of Figs. 10 and 11 as shown in Table 3 to illustrate the effect of defect thickness at normal incidence.
Hence, from Table 3, we have found that the sensitivity strongly depends on the thickness of the defect layer in saline water. Wherein the optimum performance of the proposed salinity sensor is achieved when the defect layer thickness is equal to 220 nm owing to our optimization procedure as in Refs.50,51.
To illustrate the perfection of the proposed work, we finally compared the numerical values of S, Q, and FoM of our design with the same type of study work published in numerous prestigious journals. Table 4 presents the comparison information. In Table 4, we compare the different types of salinity sensors. First, we insert the results of different structures of the planner, and we find that the maximum sensitivity is achieved at the Saw Tooth structure, which equals 612.3 nm/RIU. Then, we compare our work with the previous work on the same topic of 1D-annular PCs, and we find that our structure has the optimum performance as the sensitivity equals 782 (nm/RIU). Hence, the statistics in Table 4 make it abundantly evident that the sensitivity of the salinity sensor constructed of 1D-annular PCs is greatly improved when compared to the sensitivity of the salinity sensor made of planar structures with different surface morphologies. In addition, compared to the salinity sensor formed of planar photonic structures, the quality factor and figure of merit values of the suggested structure have increased. This contrast supports our claim that a salinity sensor formed of annular PCs might be preferable to one made of planar structures. Additionally, there is a chance to investigate this work further to create alternative annular PC-based sensing systems with the intention of researching different fluids to be used as biosensors.
Conclusion
In this paper, we succeeded in building up a 1D annular PCs structure in the form ({(AB)}^{N}), where A and B are (Si) and (Si{o}_{2}), with the materials’ thicknesses indicated by 40 nm and 70 nm, respectively, (N=9), by including a layer of central defect of saline water (({d}_{w}=220 nm)). We used COMSOL Multiphysics as a simulation tool, which depends on the FEM. Therefore, we get the optimum sensor performance as follows: the sensitivity (S) equals (782 (nm/RIU)), the quality factor (Q) equals 10.22, and the figure of merit (FOM) equals (12.6 {RIU}^{-1}). We compare our structure of 1D annular PCs with different structures of 1D-PCs such as planners, texturing, and saw tooth structures from recently published papers, as shown in Table 4. In addition, we compare our design with different structures of the same type (1D annular PCs). Hence, the findings presented in this paper contribute to the advancement of photonic crystal-based sensing technologies and pave the way for future developments in the field of salinity sensing, as annular 1D photonic crystals hold great promise for salinity sensing applications.
Data availability
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
-
Sayed, H., Krauss, T. F. & Aly, A. H. Versatile photonic band gap materials for water desalination. Optik Int. J. Light Electron Opt. 219, 165160 (2020).
Google Scholar
-
Sayed, H., Aly, A. H. & Krauss, T. F. Photonic crystals umbrella for thermal desalination: Simulation study. Sci. Rep. 12, 21499 (2022).
Google Scholar
-
Fan, S. & Joannopoulos, J. D. Analysis of guided resonances in photonic crystal slabs. Phys. Rev. B 65(23), 235112 (2002).
Google Scholar
-
H. Sayed, S. Alamri, Z. Matar and A.H. Aly, Salinity Sensor Based on 1D Photonic Crystals by Tamm Resonance with Different Geometrical Shapes. Plasmonic (2021).
-
Ali, N. B. et al. High sensitivity to salinity-temperature using one-dimensional deformed photonic crystal. Coatings 11, 713 (2021).
Google Scholar
-
Qutb, S. R., Aly, A. H. & Sabra, W. Salinity and temperature detection for seawater based on a 1D-defective photonic crystal material. Int. J. Modern Phys. B 35(01), 2150012 (2021).
Google Scholar
-
Sayed, H. & Aly, A. H. Salinity optical sensor by using two-dimensional photonic crystals: Computational study. Mater. Sci. Eng. B 269, 115169 (2021).
Google Scholar
-
Sayed, H. et al. Performance analysis of the salinity based on hexagonal two-dimensional photonic crystal: Computational study. Sci. Rep. 12, 22133 (2022).
Google Scholar
-
Armani, A. M. et al. Label-free, single-molecule detection with optical microcavities. Science 317(5839), 783–787 (2007).
Google Scholar
-
Yetisen, A. K. et al. Photonic hydrogels for rapid monitoring of water content in organic solvents. ACS Appl. Mater. Interfaces 5(16), 8003–8007 (2013).
-
Gandhi, S. & Suneet Kumar, A. Detection of wide variety of pathogens by using one-dimensional biosensor based on annular photonic crystal. Mater. Today Proc. https://doi.org/10.1016/j.matpr.2023.05.203 (2023).
Google Scholar
-
Gandhia, S., Awasthi, S. K. & Aly, A. H. Biophotonic sensor design using a 1D defective annular photonic crystal for the detection of creatinine concentration in blood serum. RSC Adv. 11, 26655–26665 (2021).
Google Scholar
-
Ameen, A. A. et al. Towards promising platform by using annular photonic crystals to simulate and design useful mask. Photonics 8, 349 (2021).
Google Scholar
-
Wu, Y.-K. et al. Photonic crystal surface waves for optical biosensors. Biosensors Bioelectron. 55, 147–156 (2014).
Google Scholar
-
Abdulkarem, H. M. et al. A theoretical approach for a new design of an ultrasensitive angular plasmonic chemical sensor using black phosphorus and aluminum oxide architecture. RSC Adv. 13, 16154–16164 (2023).
Google Scholar
-
Zhang, J. et al. Advances in atomic layer deposition. Nanomanuf. Metrol. 5, 191–208 (2022).
Google Scholar
-
Paul, A. K. Design and analysis of photonic crystal fiber plasmonic refractive Index sensor for condition monitoring of transformer oil. OSA Continuum 3(8), 2253–2263 (2020).
Google Scholar
-
Akter, S. et al. Highly sensitive refractive index sensor for temperature and salinity measurement of seawater. Optik 216, 164901 (2020).
Google Scholar
-
Monfared, Y. E. Overview of recent advances in the design of plasmonic fiber-optic biosensors. Biosensors 10(7), 77 (2020).
Google Scholar
-
Sanjeev, S. & Alireza, A. Study of optical reflectance properties in 1D annular photonic crystal containing double negative (DNG) Metamaterials. Phys. B Condens. Matter 489, 67–72 (2016).
Google Scholar
-
Li, T. et al. Recent advances in photonic crystal-based sensors. Coord. Chem. Rev. 475, 214909 (2023).
Google Scholar
-
Shinn, M. & Robertson, W. M. Surface plasmon-like sensor based on surface electromagnetic waves in a photonic band-gap material. Sensors Actuators B Chem. 105(2), 360–364 (2005).
Google Scholar
-
Sun, J. & Chan, C. C. Photonic bandgap fiber for refractive index measurement. Sensors Actuators B Chem. 128(1), 46–50 (2007).
Google Scholar
-
Adibi, A. et al. Design of photonic crystal optical waveguides with singlemode propagation in the photonic bandgap. Electron. Lett. 36(16), 1376–1378 (2000).
Google Scholar
-
Gat, N. Imaging spectroscopy using tunable filters: A review. Wavelet Appl. VII 4056, 50–64 (2000).
Google Scholar
-
James, K. R., Cant, B. & Ryan, T. Responses of freshwater biota to rising salinity levels and implications for saline water management: A review. Austr. J. Bot. 51(6), 703–713 (2003).
Google Scholar
-
Tousoulis, D., Antoniades, C. & Stefanadis, C. Evaluating endothelial function in humans: A guide to invasive and non-invasive techniques. Heart 91(4), 553–558 (2005).
Google Scholar
-
Gholizadeh, M. H., Melesse, A. M. & Reddi, L. A comprehensive review on water quality parameters estimation using remote sensing techniques. Sensors 16, 1298. https://doi.org/10.3390/s16081298 (2016).
Google Scholar
-
Adjovu, G. E., Stephen, H., James, D. & Ahmad, S. Overview of the application of remote sensing in effective monitoring of water quality parameters. Remote Sens. 2023, 15. https://doi.org/10.3390/rs15071938 (1938).
Google Scholar
-
Robinson, S. & Nakkeeran, R. PC based optical salinity sensor for different temperatures. Photonic Sensors https://doi.org/10.1007/s13320-012-0055-6 (2012).
Google Scholar
-
Shamshiri, R. R., Balasundram, S. K., Kaviani Rad, A., Sultan, M. & Hameed, I. A. An overview of soil moisture and salinity sensors for digital agriculture applications. In Digital Agriculture, Methods and Applications (eds Shamshiri, R. R. & Shafian, S.) (IntechOpen, 2022). https://doi.org/10.5772/intechopen.103898.
Google Scholar
-
Chen, M.-S., Wu, C.-J. & Yang, T.-J. Optical properties of a superconducting annular periodic multilayer structure. Solid State Commun. 149, 1888–1893. https://doi.org/10.1016/j.ssc.2009.08.002 (2009).
Google Scholar
-
Yusuf, A. et al. A review of emerging trends in membrane science and technology for sustainable water treatment. J. Clean. Prod. 266, 121867 (2020).
Google Scholar
-
Quan, X. H. & Fry, E. S. Empirical equation for the index of refraction of seawater. Appl. Opt. 34, 3477–3480 (1995).
Google Scholar
-
Li, X., Yang, X. & Ma, J. Design of photonic crystal cavity based on annular lattice for refractive index sensing. Optics Express 21(10), 12139–12148 (2013).
-
Zhou, R., Cai, L. & Yang, G. Tunable annular photonic crystal slabs for on-chip refractive index sensing. J. Appl. Phys. 118(19), 193106 (2015).
-
Wang, J., He, Y. & Liu, H. Design of photonic crystal fiber refractive index sensor based on bandgap shift. J. Phys. Conf. Ser. 1124(1), 012063 (2018).
-
Zhao, Z., Li, F. & Wang, G. Design of an annular photonic crystal fiber with high birefringence and large flattened negative dispersion. Chin. Optics Lett. 13(1), 011604 (2015).
-
Hale, G. M. & Querry, M. R. Optical constants of water in the 200-nm to 200-µm wavelength region. Appl. Opt. 12, 555–563 (1973).
Google Scholar
-
Langer, H. & Offermann, H. On the solubility of sodium chloride in water. J. Crystal Growth 60(2), 389–392 (1982).
Google Scholar
-
https://www.britannica.com/science/seawater.
-
Byrne, Robert Howard, Mackenzie, Fred T. and Duxbury, Alyn C. “Seawater”. Encyclopedia Britannica, 28 Apr. 2022. https://www.britannica.com/science/seawater. Accessed 26 October 2022.
-
Liquid water source: http://www1.lsbu.ac.uk/water/vibrat.html#uv.
-
Vigneswaran, D. et al. Salinity sensor using photonic crystal fiber. Sensors Actuators A 269, 22–28 (2018).
Google Scholar
-
Amiri, I. S. et al. “Tri-core photonic crystal fiber based refractive index dual sensor for salinity and temperature detection. Microwave Opt. Technol. Lett. 61(3), 847–852 (2019).
Google Scholar
-
Aspnes, D. E. & Studna, A. A. Dielectric functions and optical parameters of Si, Ge, GaP, GaAs, GaSb, InP, InAs, and InSb from 1.5 to 6.0 eV. Phys. Rev. B 27, 985–1009 (1983).
Google Scholar
-
Aly, A. H. & Sayed, H. Photonic band gap materials and monolayer Solar cell. Surf. Rev. Lett. 25(8), 1850103 (2018).
Google Scholar
-
Pathania, P. & Shishodia, M. Gain-assisted transition metal ternary nitrides (Ti1−xZrxN) core-shell based sensing of waterborne bacteria in drinking water. Plasmonics https://doi.org/10.1007/s11468-019-00927-8 (2019).
Google Scholar
-
Tan, T., Srivastava, Y., Manjappa, M., Plum, E. & Singh, R. Lattice induced strong coupling and line narrowing of split resonances in metamaterials. Appl. Phys. Lett. 112, 201111. https://doi.org/10.1063/1.5026649 (2018).
Google Scholar
-
Huang, K. et al. A proposal for a high-sensitivity optical MEMS accelerometer with a double-mode modulation system. J. Lightwave Technol. 39(1), 303–309 (2021).
Google Scholar
-
Huang, K., Yu, M., Cheng, L., Liu, J. & Cao, L. A proposal for an optical MEMS accelerometer with high sensitivity based on wavelength modulation system. J. Lightwave Technol. 37(21), 5474–5478 (2019).
Google Scholar
-
Sayed, H. et al. Salinity sensor based on 1D photonic crystals by tamm resonance with different geometrical shapes. Plasmonics 17, 409–422 (2022).
Google Scholar
-
Klimov, V. V., Pavlov, A. A., Treshinand, I. V. & Zabkov, I. V. Fano resonances in a photonic crystal covered with a perforated gold film and its application to bio-sensing. J. Phys. D Appl. Phys. 50, 285101 (2017).
Google Scholar
-
Lheureux, G. et al. Tamm plasmons in metal/nanoporousGaN distributed Bragg reflector cavities for active and passive optoelectronics. Opt. Express 28(12), 17934–17943 (2020).
Google Scholar
-
Gandhi, S., Kumar Awasthi, S. & Aly, A. H. Biophotonic sensor design using a 1D defective annular photonic crystal for the detection of creatinine concentration in blood serum. RSC Adv. 11, 26655–26665 (2021).
Google Scholar
-
Gandhi, S. & Kumar Awasthi, S. Detection of wide variety of pathogens by using one-dimensional biosensor based on annular photonic crystal. Mater. Today Proc. https://doi.org/10.1016/j.matpr.2023.05.203 (2023).
Google Scholar
Acknowledgements
This publication is made possible by the generous support of the American people through the United States Agency for International Development (USAID). The contents are the responsibility of Hassan Sayed and do not necessarily reflect the views of USAID or the United States Government.
Funding
Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with the Egyptian Knowledge Bank (EKB).
Author information
Authors and Affiliations
Contributions
H.S and A.H.A. conceived the main idea and the designed structure. H.S, A.H.A., and M.S. designed and conducted the analyses and software. H.S. wrote the manuscript with support from A. H.A. and M.S. In addition, A. H.A. supervised this work. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and Permissions
About this article
Cite this article
Sayed, H., Swillam, M.A. & Aly, A.H. Annular one-dimensional photonic crystals for salinity sensing.
Sci Rep 13, 20593 (2023). https://doi.org/10.1038/s41598-023-47205-6
-
Received: 04 September 2023
-
Accepted: 10 November 2023
-
Published: 23 November 2023
-
DOI: https://doi.org/10.1038/s41598-023-47205-6
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.